Updated White Paper discusses benefits and risks of Eco-mode and Advanced Eco-mode UPS operation

Operating a double-conversion UPS in Economy mode saves energy but sacrifices some security. Advanced Economy-mode offers a third alternative.

The growing financial and environmental costs associated with the energy used to power data centres has given rise to an appropriate drive to improve the efficiency of power and cooling equipment.


Schneider Electric's White Paper 157 “Eco-mode: Benefits and Risks of Energy-saving Modes of UPS Operation” originally focused on the technique of operating a double-conversion UPS in bypass mode to improve its power efficiency. A newly updated version, while retaining a discussion of the benefits and risks of this technique, known as Eco-mode, now discusses in addition an alternative energy-efficient mode known generically as advanced Eco-mode.


Standard Eco-mode is very similar to the basic mode of operation used in an offline UPS where it is called “standby” or “line interactive” mode. In these traditionally smaller, single-phase UPSs, the inverter/rectifier circuits are “offline” or are not part of the normal power path. In normal operation, therefore, the load is exposed to essentially raw mains power from the Utility. A similar mode of operation occurs with a double-conversion online UPS operating in traditional Eco-mode.


The benefit of Eco-mode is that it results in a pickup in UPS efficiency of between 2 and 5%. The cost of Eco-mode is that the IT load is exposed to raw utility mains power without the conditioning normally provided by the double-conversion, online UPS. Also, the UPS must continuously monitor the mains power and quickly switch to the UPS inverter when a problem is detected, before the problem can affect the critical load. There is therefore a slightly increased risk to the load when using Eco-mode.


In Schneider Electric's implementation of Advanced Eco-mode the primary power path during normal operation is the same as traditional Eco-mode: through the bypass path. But with advanced Eco-mode, the inverter remains “on”, operating in parallel with the input without actually handling the load current. Since the inverter is already “on”, it can more seamlessly take over the supply to the output where there is a mains failure.


There is a slight penalty to be paid in terms of energy efficiency, compared with traditional Eco-mode but advanced Eco-mode is still more efficient than running the UPS in standard line-interactive mode.

Written by Neil Rasmussen, Senior VP for Innovation at Schneider Electric, white paper 157 helps to answer questions about the technology such as what is Eco-mode and how does it work? How does advanced Eco-mode offer an improved alternative? What efficiency gains are possible and what could be expected using either mode? What are the operational considerations of the technology?

First of its kind research, in partnership with Canalys, offers deep insights into some of the...
According to a recently published report from Dell’Oro Group, worldwide data center capex is...
Managed service providers (MSPs) are increasing their spending by as much as 70% to meet growing...
Coromatic, part of the E.ON group and the leading provider of robust critical infrastructure...
Datto’s Global State of the MSP: Trends and Forecasts for 2024 underscores the importance of...
Park Place Technologies has appointed Ian Anderson as Senior Director, Channel Sales, EMEA.
Node4 has passed the ISO 27017 and ISO 27018 audits, reinforcing its dedication to data security,...
Park Place Technologies has acquired Xuper Limited, an IT solutions provider based in Derby, UK.